執行標準:
1. GB2423.16—90試(shi)驗J—長(chang)霉試(shi)驗方法
2. GJB150.10—86,設(she)備霉菌試驗
3. GJB4.10-83艦船電子設備環境(jing)試驗霉菌試驗
4. GB—2002長霉試(shi)驗(yan) GB2002濕熱試(shi)驗(yan)
主要技(ji)術規(gui)格及(ji)參數:
1. JL-JMS-150 工作室尺寸(cun): 500(D)×500(W)×600(H)mm
2. 溫度范(fan)圍: 10℃ ~+80℃
3. 濕度(du)范(fan)圍: 45%~98%
4. 溫(wen)度波動度: ≤±0.5℃
5. 溫度均(jun)勻度: ≤±2℃
6. 濕度波動度: ≤±2%
7. 溫(wen)度(du)均勻度(du): ≤±3%
8. 功 率: 5Kw
9. 整 機噪音: ≤70db
10. 加濕(shi)方式: 淺(qian)槽(cao)式加濕(shi)
11. 風 速: 0.5~1M/S
12. 自動換氣(qi)裝置(zhi),換氣(qi)量為3.2m3/h,換氣(qi)期間(jian)指示(shi)點(dian)(dian)溫度不(bu)超出設定(ding)值±1℃的范圍,相(xiang)對濕度不(bu)小于85%,換氣(qi)結束時(shi),指示(shi)點(dian)(dian)溫度、濕度在20min內(nei)恢復(fu)到(dao)試驗條件。
13. 加濕(shi)用水(shui):采用清潔的蒸餾水(shui)或干凈清潔的蒸餾水(shui)及其(qi)他軟水(shui),加濕(shi)用水(shui)的電阻率≥500Ω·m2.
14. 制冷系統冷卻(que)方式(shi):風冷式(shi)
15. 溫度、濕度控(kong)制采用程序控(kong)制方式,用戶可設(she)定升溫、降溫速率及恒(heng)溫時間(jian)。對于增濕、除濕及恒(heng)濕工(gong)況,設(she)備能按(an)設(she)定的曲線自動運行(xing)。
16. 工作條件(jian): 電源:380V±10%,50Hz
試(shi)驗(yan)箱(xiang)箱(xiang)體結構
1. 整個箱體(ti)采用整體(ti)結(jie)構,分為三個部分,上部為工作室(shi)(shi),下部為機械室(shi)(shi)。左側(ce)是控制夾(jia)層。
2. 箱體內側采用1.0mm進口SUS321不銹鋼板,外側鋼板噴塑。
3. 保溫材質為超細玻璃保溫棉。
4. 加熱方式: 空氣電加熱(夾套內)
5. 加濕方(fang)(fang)式: 幕布加濕方(fang)(fang)式、加濕泵選用磁力(li)泵
6. 在箱體側面設有帶塞子的φ50mm測試孔,配備孔蓋。
7. 工作室配置(zhi)2層網(wang)狀試品(pin)架,高度可自動調節,材質為不(bu)銹鋼
8. 溫濕度(du)傳感器置(zhi)于出風(feng)口。
9. 箱體的換氣(qi)(qi)裝置(zhi)(zhi)加有微(wei)生(sheng)物過濾(lv)(lv)器,換氣(qi)(qi)時閥門自動(dong)打開并將過濾(lv)(lv)后的氣(qi)(qi)體由離心(xin)風機經管道(dao)排(pai)出室外,管道(dao)配(pei)置(zhi)(zhi)長度(du)zui少5米(mi)。
10. 設有雙層鋼化玻璃觀察窗,厚度為(wei)8mm。
11. 機(ji)械(xie)裝(zhuang)配和電氣裝(zhuang)配參照DJ20132-92電子(zi)(zi)設備機(ji)械(xie)裝(zhuang)配技(ji)術(shu)(shu)要求和SJ20385電子(zi)(zi)設備電氣裝(zhuang)配技(ji)術(shu)(shu)要求。制冷系統
1. 低溫制冷采用法國(guo)“泰康”全封(feng)閉(bi)式(shi)壓縮機,其它制冷部件如美國(guo)RANCO、SPOLAN、丹(dan)麥DANFOSS、意大利CAS、日本(ben)鷺(lu)宮等*產品。使(shi)用R404A環保型(xing)制冷劑。
2. 濕熱試驗采用節能效果良好(hao)的高溫級(ji)壓縮機除濕。
3. 蒸發器采用主副兩個蒸發器并聯,主蒸發器采用翅片式蒸發器,作為低溫制冷時用。副蒸發器采用光管蒸發器,作為除濕降溫時使用。主副蒸發器由兩組電磁閥分別控制,以滿足試驗條件下任意工況的制冷或除濕。
4. 為確保系(xi)統(tong)(tong)安全運行,在(zai)系(xi)統(tong)(tong)中需(xu)設置高低(di)(di)壓控制 、 超(chao)壓 、 過載等保護系(xi)統(tong)(tong)。同時為了監測(ce)系(xi)統(tong)(tong)運行情況,在(zai)高低(di)(di)壓端均需(xu)設有高低(di)(di)壓表監測(ce)系(xi)統(tong)(tong)運行情況。
5. 制(zhi)冷量調節采用分流法。
6. 其(qi)它(ta)制冷(leng)部件均采(cai)用美國RANCO、SPOLAN、瑞士“ALFALAVAL”、丹麥(mai)DANFOSS、意大利CAS、日本鷺宮等*產品。
加濕系統
1. 由加濕、除濕、自動供水、斷水保護及濕度測控等部分組成。
2. 加(jia)(jia)(jia)濕(shi)(shi)采(cai)用(yong)淺槽式加(jia)(jia)(jia)濕(shi)(shi)法。濕(shi)(shi)度(du)測量采(cai)用(yong)干濕(shi)(shi)球方法,由(you)程序控制(zhi)器自動(dong)完成并(bing)控制(zhi)加(jia)(jia)(jia)濕(shi)(shi)實現加(jia)(jia)(jia)濕(shi)(shi)功能,同時將(jiang)濕(shi)(shi)度(du)值(zhi)直接顯示出來。
3. 加(jia)濕器需采用(yong)耐高(gao)溫、絕(jue)緣性好、使用(yong)壽命長的全(quan)封閉不銹鋼(gang)加(jia)熱管(guan)。
4. 設置有自動供(gong)水裝置,以防止由于水的不斷蒸發而(er)消(xiao)耗水箱中(zhong)的水。
控制系統
控(kong)(kong)(kong)制(zhi)系統(tong):采用(yong)韓國(guo)(guo)進口“TEMI880” 5.7寸真彩觸摸(mo)屏可編程(cheng)(cheng)溫(wen)濕(shi)度控(kong)(kong)(kong)制(zhi)儀表,與法國(guo)(guo)施奈德、日本富土等電(dian)(dian)氣元(yuan)器(qi)(qi)件構(gou)成電(dian)(dian)氣控(kong)(kong)(kong)制(zhi)系統(tong)。控(kong)(kong)(kong)制(zhi)器(qi)(qi)采用(yong)全(quan)中(zhong)文菜單操作方式(shi),zui小顯示分辨率0.01℃,運行(xing)(xing)(xing)方式(shi):定值和(he)程(cheng)(cheng)序(xu)(xu)運行(xing)(xing)(xing)。控(kong)(kong)(kong)制(zhi)方式(shi):連(lian)(lian)續PID控(kong)(kong)(kong)制(zhi)。可設(she)定曲(qu)線(xian)(xian)不(bu)少(shao)于30條程(cheng)(cheng)序(xu)(xu)曲(qu)線(xian)(xian),可設(she)定斷電(dian)(dian)恢復設(she)定,包(bao)括:斷電(dian)(dian)后(hou)程(cheng)(cheng)序(xu)(xu)終止(zhi)執行(xing)(xing)(xing)、斷電(dian)(dian)后(hou)程(cheng)(cheng)序(xu)(xu)從(cong)斷點連(lian)(lian)續運行(xing)(xing)(xing)。在控(kong)(kong)(kong)制(zhi)系統(tong)中(zhong)需設(she)有安(an)全(quan)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)措施,包(bao)括:缺(que)相(xiang)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、相(xiang)序(xu)(xu)錯誤保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、相(xiang)電(dian)(dian)壓(ya)(ya)(ya)不(bu)平(ping)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、風機(ji)過(guo)載(zai)(zai)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、超溫(wen)、斷電(dian)(dian)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、機(ji)組(zu)高壓(ya)(ya)(ya)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、機(ji)組(zu)低壓(ya)(ya)(ya)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、機(ji)組(zu)過(guo)載(zai)(zai)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、機(ji)組(zu)過(guo)溫(wen)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、缺(que)水(shui)(shui)保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)、漏電(dian)(dian)等保(bao)(bao)(bao)(bao)護(hu)(hu)(hu)(hu)(hu)。在電(dian)(dian)氣控(kong)(kong)(kong)制(zhi)系統(tong)中(zhong)設(she)有互鎖(suo)裝(zhuang)置,當(dang)循(xun)環風機(ji)沒有啟動或過(guo)載(zai)(zai)時制(zhi)冷(leng)機(ji)組(zu)和(he)加(jia)熱系統(tong)不(bu)能啟動,機(ji)組(zu)超高壓(ya)(ya)(ya)、超低壓(ya)(ya)(ya)、過(guo)載(zai)(zai)時制(zhi)冷(leng)機(ji)組(zu)都將被禁止(zhi),缺(que)水(shui)(shui)時不(bu)能啟動加(jia)濕(shi)器(qi)(qi)。試驗(yan)箱非電(dian)(dian)源部分不(bu)漏電(dian)(dian),不(bu)積存靜電(dian)(dian)
關鍵配置
1. 儀 表:韓國進口“TEMI880”液晶顯示觸摸屏溫濕度控制器
2. 機 組:進口原裝法國“泰康”全封閉式制冷機組。
3. 壓力控制器、電磁閥、手閥、干燥過濾器、蒸發器、膨脹閥:選用進口的優質產品。
4. 電器元件:法國“施奈德”交流接觸器、開關、按鈕、日本富士小型繼電器等產品
5. 傳 感 器:Pt100。
6. 電源開關:帶漏電保護。
隨機資料
設備的合格證、保修卡、裝箱單、設備使用說明書、儀表和個電器使用說明書、設備電氣原理圖、隨機零配件、易損件備件等
交 貨 說 明
供(gong)方負責送貨上(shang)門,安(an)裝調試(shi)操作介紹,直到(dao)(dao)需方員工(gong)獨(du)立操作為止。質(zhi)量保修(xiu)期壹年,自安(an)裝驗收之日起計。供(gong)方承(cheng)諾終(zhong)生提供(gong)備件,售后服務(wu)必須(xu)到(dao)(dao)現場(chang)解決的,供(gong)方在(zai)客戶時間(jian)之內到(dao)(dao)達現場(chang)。